Select Page

STEAM STERILIZER

LTSF 2% – 130LF®

STEAM STERILIZER LTSF 2% – 130LF®

130LF® STERILIZER

Maximum efficiency with minimum % of formaldehyde

The estimated 80 % speed increase combined with a sterilizing solution of only 2 % formaldehyde and high penetrability, positions the new 130LF® at the forefront of LTSF  technology and makes it the perfect solution for multichannel/complex endoscopy sterilization.

A wide spectrum of advantages to suit all your needs

SPEED

12 kg treated in 90 min!

This cycle time turns the 130LF® sterilizer into the fastest on the market.

PENETRABILITY

The penetrating power of the 130LF® sterilizer makes it possible to sterilize complex, multi-channel cannulated instruments up to 3 m in length and 0.5 mm in internal diameter.

GENTLE WITH INSTRUMENTS

LTSF technology is more delicate with instruments compared to other low temperature sterilization systems.

STERILIZING SOLUTION EXPIRY DATE

The e-bag® sterilizing solution has a shelf life of 36 months! For greater flexibility in inventory management.

SAFETY

Safe handling of the sterilizing solution. 2 % formaldehyde only. Integrated osmosis system for an optimal rinsing.

DESIGN

Modern and minimalist design to facilitate the cleaning process.

EASY USE

Intuitive EasyRUN user interface.
Status of the unit visible from a distance, thanks to the backlit front panel.
Easy and quick learning by users.

ERGONOMICS

Automatic bag perforation system. Extensible and removable shelves for ease and flexibility during the loading process.

CONNECTIVITY & DOCUMENTATION

Built-in thermal printer.
Large capacity internal memory with a track record of the last 1000 cycles.
USB port that allows backup of cycle logs.
Ethernet port for connection to monitoring and traceability software.

LTSF sterilizing solution

36 month-shelf life! For greater flexibility in stock management.

Maximum safety LTSF a safe technology for patients, users and gentle on the environment
LTSF technology has been developed in conjunction with international independent research and scientific support, giving priority to all aspects related to safety.

PATIENT SAFETY FIRST

Residues on medical devices 28 % below the limits stipulated in the European Standard EN 14180. While the average value limit is 200µg, the value measured in medical devices sterilized in 130LF® is 145µg.

HIGHEST RESPECT FOR THE ENVIRONMENT

Residues in drains far from local boundaries. The 0.2 g of formaldehyde per litre of water measured directly in the drainage of the 130LF® sterilizer is well below average limit levels, thus ensuring respect for the environment.

GUARANTEED USER SAFETY

The 0.04 ppm (0.051 mg / m3) measured when operating the 130LF® sterilizer are: 7 times lower than the lowest European 8 hours exposure limit of 0.3 ppm (0.37 mg / m³), ​​in compliance with the DIRECTIVE (EU) 2019 / 983. 2 times lower than the lowest value in the application range of LTSF sterilizers in the world, prescribed in Japan at 0.1 ppm (OEL). More than 18 times lower than the permissible exposure limit (PEL) declared by OSHA of 0.75 ppm (TWA).

FORMALDEHYDE

Formaldehyde is a substance found in nature and metabolized daily by our body (≈ 50 mg/day). Formaldehyde content: Coffee…………………………….. 50 mg/liter Apples……………………………. 17.3 mg/kg Pears ……………………………… 60 mg/kg Pork ……………………………….. 20 mg/kg Cheese and milk……………… up to 3.3 mg/kg Codfish ………………………….. 20 mg/kg Crustaceans (ocean)………… from 3 to 98 mg/kg Onion ……………………………. 13.3 mg/kg
Feel the SPEED!!!!!!

2 Techs 1 Aim
Know more about other Low Temperature Techs

DOCUMENT DOWNLOAD

ES | EN | FRDEPTIT